Our handcrafted combined three-pass pellet boiler for the automatic combustion of granular biomass (pellets, fruit kernels), with the option of manual heating with solid fuels via the central door of the boiler. The Šukom VENT boiler is the ideal boiler for combined heating and is unique in its design.
The heat exchanger, or rather the convective part of the boiler, is designed based on correctly adjusted flue gas velocities to minimize abrasion of the heat exchanger material. Turbulators are provided inside the heat exchanger tube (quality P.235 GHTC 1) to
To increase heat transfer and efficiency of the boiler. All parts of the boiler are easily accessible for service and maintenance. In short, the boiler consists of
A robust, high-quality construction based on many years of experience in this field. Granular biomass is fired via a screw conveyor on the side of the boiler. The granular material is stored in the dosing hopper, below which the screw conveyor, via a rotating conveyor, collects the fuel and transports it to the fluidized bed chamber. The volume of the dosing hopper is tailored to the boiler's daily needs. The hopper can be positioned on the left or right. The combustion box, including the dosing unit, is removable. Granular biomass is ignited fully automatically via an electric fire igniter. For the combustion of granular material, only artificial air is used, provided by the primary and flue gas fans, which are selected to provide a sufficient amount of air for combustion and fluidization. The air introduced into the fluidized bed chamber is divided into primary and secondary air, while a portion of the air is also fed into the screw conveyor to prevent the flame from the combustion zone from recirculating into the dosing hopper. The combustion of solid fuel (logs, briquettes, coal) takes place in the front part of the combustion chamber and is controlled by the combustion regulator, which moves the damper on the lower door and thus regulates the amount of combustion air. In this case, only the flue gas fan runs, while the primary air fan is off. By installing a sedimentation chamber at the rear of the boiler and a flue gas fan, the boiler is maintained at negative pressure, eliminating the risk of the flame returning to the dosing hopper or the door.
In case of increased pressure, the connection for a safety valve is located at the prescribed location, while the boiler is protected against elevated temperatures by the installation of a safety heat exchanger, which cools the boiler when necessary. The boiler body is insulated with mineral wool, and the boiler sheets are protected by painting and powder coating.
What speaks for our boiler?
- Robust and reliable construction - unique and patented design.
- Pure steel boiler with built-in material of grade P265GH and P235GHTC1 with 6mm thickness!
- no moving parts in the boiler room, thus no risk of unwanted defects
- Robust dosing system with chain drive
- Easy operation and maintenance
- Control unit 4" touchscreen including WiFi module
Selection of 10 different hydraulic systems
18 external connections
6 configurable ports
Connection to a room thermostat
Connection for the buffer tank
Connection for the pump group
Winter and summer time mode
Weather control
Connection to expandable pellet transport
Remote control/monitoring via APP and much more.
- Two-part combustion chamber for pellets and logs - Easy switching to emergency wood operation - Combined operation of logs and pellets possible automatically without any conversion work!
- Wood operation without energy source with combustion controller
- Fluidized bed combustion - enables good momentum and heat exchange, largely prevents the formation of thermal nitrogen oxide due to the lower combustion temperatures.
- High water content for better heat transfer and better fuel efficiency
- Primary and secondary air supply ensure smooth operation and maintenance of the set temperature
- Sedimentation chamber with flue gas fan, which serves to maintain negative pressure in the boiler, thus preventing flame recirculation and simultaneously cleaning the flue gases of larger particles. (Mechanical fine dust filter)
- Pellet container can be moved to either side.
You're getting an absolute long-lasting runner with the highest quality craftsmanship, handcrafted in an industrial design! The G-Class among boilers!
Pellet heating combination boiler Sukom Vent 25-80 TS
Return Policy
At ENERGYHEAT, we want to ensure you are satisfied with your purchase. However, should you be dissatisfied with your product for any reason, we offer a return option in accordance with the following guidelines:
Return period: You have 14 days from the date of receipt to return the product. After this period, we unfortunately cannot accept any returns.
Product condition: The product must be unused and undamaged to be eligible for a return. It should be returned in its original packaging with all accessories and labels.
Return procedure: To initiate a return, please contact our customer service department by phone or email. Our staff will be happy to assist you and explain the necessary steps for the return.
Return shipping costs: The customer is responsible for the return shipping costs unless the product has a manufacturing defect or has been damaged in transit. In this case, we will cover the return shipping costs.
Refund: Once we have received and inspected the returned product, we will refund the purchase price. The refund will be issued via the same payment method you used for the purchase.
Please note that certain products may be excluded from returns due to their nature. This applies in particular to custom-made items, personalized products, or products that cannot be returned for reasons of health protection or hygiene.
We hope you are satisfied with your purchase from ENERGYHEAT. However, should you have any questions or concerns regarding our return policy, please do not hesitate to contact us. Our customer service team is happy to assist you.