top of page

Description

Our hand-made combined three-pass boiler for the automatic combustion of granular biomass (pellets, fruit kernels), with the possibility of manual heating with solid fuel on the central door of the boiler. The Šukom VENT boiler type is the ideal boiler for combined heating and is unique in its design. The heat exchanger, or the convective part of the boiler, is designed on the basis of correctly adjusted flue gas velocities in order to keep the abrasion of the heat exchanger material as low as possible. Turbulators are provided inside the heat exchanger tube (quality P.235 GHTC 1) to increase the heat transfer and the efficiency of the boiler. All parts of the boiler are easily accessible for service and maintenance. In short, the boiler consists of a robust and high-quality construction based on many years of experience in this field. The firing of granular biomass takes place via the screw conveyor on the side of the boiler. The granular material is stored in the dosing container, under which the screw conveyor picks up the fuel via a rotary conveyor and transports it to the fluidized bed chamber. The volume of the dosing container is tailored to the daily needs of the boiler. The container can be positioned on the left or right. The firebox including the dosing unit is removable. The ignition of granular biomass occurs fully automatically using an electric fire igniter. For the combustion of granular material, only artificial draft is used with the help of the primary and flue gas fans selected to provide a sufficient amount of air for combustion and fluidization. The air introduced into the fluidized bed chamber is divided into primary and secondary air, while part of the air is also introduced into the screw conveyor to prevent the return of the flame from the combustion zone to the dosing container. The combustion of solid fuel (logs, briquettes, coal) takes place in the front part of the firebox and is controlled by the fire regulator, which moves the flap on the lower door and thus regulates the amount of combustion air. In this case, only the flue gas fan runs while the primary air fan is switched off. By installing a sedimentation chamber at the back of the boiler and a flue gas fan, the boiler is kept at negative pressure and there is no risk of the flame returning to the dosing container or the door. At increased pressure, the connection for a safety valve is in the prescribed place, while securing the boiler against elevated temperatures is done by installing a safety heat exchanger that cools the boiler when necessary. The boiler body is insulated with mineral wool and the boiler sheets are protected by painting and powder coating processes.

 

What speaks for our boiler?

- Robust and reliable construction

- unique and patented structure.

- Pure steel boiler with built-in material of quality P265GH and P235GHTC1 with 6mm thickness!

- no moving parts in the boiler room, so no risk of unwanted defects

- Robust dosing system with chain drive

- Easy operation and maintenance

- Control unit with analogue display and key buttons

Choice of 7 different hydraulic systems

14 external ports

3 configurable ports

Connection to a room thermostat

Connection for the buffer storage

Connection for mixer valve

Winter and summer time mode

Connection to expandable pellet transport

modulation

- Two-part firebox for pellets and logs

- Easy switching to emergency wood operation

- Combined operation of logs on pellets is automatically possible without any modification work!

- Wood operation without energy source with fire regulator

- Fluidized bed firing

- enables good impulse exchange and heat exchange, largely prevents the formation of thermal nitrogen oxide due to the lower firing temperatures.

- High water content for better heat transfer and better fuel efficiency

- Primary and secondary air supply ensure smooth operation and maintenance of set temperature

- Sedimentation chamber with flue gas fan, which serves to keep the boiler at negative pressure, thus preventing flame recirculation and at the same time cleaning the flue gases from larger particles. (Mechanical fine dust filter)

- Pellet container can be moved on both sides.

Here you get an absolute long-term runner and the highest workmanship quality, handcrafted in an industrial design! The G-Class among boilers!

 

scope of delivery

boiler body

Pellet container

Boiler control

Dosing unit and screw motor

Automatic detonator

Operating and assembly instructions

 

Connection fittings such as e.g. are excluded from the scope of delivery.Boiler safety group, combustion controller, sensor etc.


Brand and model: Šukom VENT 100

Power: 50-110 kW

Energy efficiency: A+

Efficiency: 93%

Max. operating pressure: 3 bar

Max. water temperature: 90°C

Chimney connection: 250mm

Heating area: approx. 450-1200 m2 for very well insulated objects, room height 3m (10cm insulation)

Emergency operation with wood/briquettes/coal, log length 70 cm

Pellet dosing container: approx. 165 kg capacity

Water content: 310l

Weight: 870kg

Warranty: 5 years manufacturer's warranty on boiler body and heat exchanger, 2 years on electrical parts

Certification: CE, EAC, TÜV AUSTRIA

German approval, BlmSchV level 2

Delivery time: 45-60 days up to 200kW power

 

Please always inquire about prices and delivery times!